Abstract

Segmental Le Fort I surgery is an effective technique to correct complicated dentomaxillofacial deformities. This retrospective study evaluated the accuracy of segmental Le Fort I surgery under the guidance of virtual surgical planning (VSP). A total of 129 patients who accepted segmental Le Fort I surgery were investigated in this study. VSP was transferred to segmental surgery with different pieces precisely with the aid of 3D-printed surgical templates and splints. The surgical result was evaluated by postoperative complications, color distance maps, and quantitative accuracy analysis. Outcomes showed that the VSP was successfully transferred to actual surgery with high accuracy. The overall mean linear difference was 1.28 mm, and the overall mean angular difference was 2.4°. Except for one case of root injury, there was no serious complication recorded. The results suggested that VSP was a reliable assistance for segmental Le Fort I surgery.