Abstract
BackgroundPhenotypic detection of extended-spectrum beta-lactamases (ESBLs) is based on the inhibition of ESBL enzymes by β-lactamase inhibitors and on the comparison of cephalosporin activity with or without a β-lactamase inhibitor. Many South African diagnostic laboratories rely on the Vitek 2 for automated susceptibility testing and for ESBL detection. However, the Gram-negative susceptibility card currently used locally (AST-N255) has been modified and its accuracy for ESBL detection is not known.MethodsWe randomly selected 50 isolates of Klebsiella pneumoniae and Escherichia coli from a collection of clinical bloodstream isolates from Groote Schuur Hospital from 2015 to 2016, including ESBL-producing and non-ESBL-producing strains. We used standardised phenotypic (disc diffusion and broth microdilution) and genotypic (conventional polymerase chain reaction (PCR) for blaCTX-M, blaSHV and blaTEM) methods for detection of ESBLs. We compared ESBL detection by Vitek 2 to a composite reference standard comprising ESBL detection either by both phenotypic methods or by one phenotypic method together with genotypic detection.ResultsThe sensitivity of Vitek 2 system for detection of ESBLs was 33/36 or 92% (78% – 97%) for E. coli, and 40/40 or 100% (91% – 100%) for K. pneumoniae, whilst specificity was 10/10 or 100% (72% – 100%) and 9/10 or 90% (60% – 98%), respectively. This is comparable with previous studies.ConclusionUsing a composite reference standard of the phenotypic and genotypic methods employed in this study, no Vitek-categorised ESBL E. coli or K. pneumoniae was found to be a non-ESBL with the exception of possible misinterpretation with K. pneumoniae SHV-hyper-producing isolates.
Highlights
Phenotypic detection of extended-spectrum beta-lactamases (ESBLs) is based on the inhibition of ESBL enzymes by β-lactamase inhibitors and on the comparison of cephalosporin activity with or without a β-lactamase inhibitor
Extended-spectrum β-lactamases are reported to be widespread in South Africa, in Klebsiella pneumoniae[2,3] and in nosocomial infections.[4]
Phenotypic methods for the detection of ESBLs are based on the inhibition of ESBL enzymes by β-lactamase inhibitors and on the comparison of cephalosporin activity with or without a β-lactamase inhibitor.[6,7,8]
Summary
Phenotypic detection of extended-spectrum beta-lactamases (ESBLs) is based on the inhibition of ESBL enzymes by β-lactamase inhibitors and on the comparison of cephalosporin activity with or without a β-lactamase inhibitor. Many South African diagnostic laboratories rely on the Vitek 2 for automated susceptibility testing and for ESBL detection. Phenotypic methods for the detection of ESBLs are based on the inhibition of ESBL enzymes by β-lactamase inhibitors and on the comparison of cephalosporin activity with or without a β-lactamase inhibitor.[6,7,8] This principle underlies both agar-based testing and broth-based testing, including automated susceptibility testing systems such as the Vitek 2 (BioMerieux, Marcy-l’Étoile, France) which is widely used in South Africa
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.