Internal dose calculations in nuclear medicine normally use the techniques, equations, and resources provided by the Medical Internal Radiation Dose (MIRD) Committee of the Society of Nuclear Medicine. The MIRD schema uses a unique set of symbols and quantities to calculate the absorbed dose of radiation in any target organ per radioactive decay in any source organ. The calculations involve the energy emitted per radioactive decay, the fraction of the emitted energy that is absorbed in various target organs, the masses of these organs, and both the physical decay and biologic clearance of the injected radioactive material. Standardized mathematical models (phantoms) of the human body and standardized biokinetic models are also used. A computer program, MIRDose, calculates dose tables per unit administered activity of various radiopharmaceuticals. Special care must be taken when nuclear medicine procedures involve pregnant or lactating patients. New methodologies are becoming available to calculate doses to individual patients.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.