Abstract
The paper presents the results of development and testing of an explosively actuated circuit-breaker (the so-called pyrobreaker) designed and manufactured at the Efremov Institute [1]. In accordance with the ITER specifications this switch will be used for continuous operation with DC currents up to 70kA and shall be capable, on command, to transfer this current to a resistive load under a voltage up to 10kV in less than 1ms.A number of current commutation tests have been carried out on several prototypes [2]. The last experimental campaign has demonstrated reliable operation of the pyrobreaker with 20% safety margin for the interrupted current and 100% margin for the recovery voltage relative to the ITER requirements.Besides, peak current withstand tests have been performed with pulse currents up to 420kA generated by the unipolar current generator available at the Efremov Institute.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.