Abstract

In this paper, we investigate the parameters affecting Total Harmonic Distortion (THD) and Power Supply Rejection Ratio (PSRR) in PWM Class D Amplifiers (CDAs) on the basis of linear models with feedback. From our mathematical analysis, we show that the THD of a PWM Class D amplifier with feedback can be improved by increasing the gain of the integrator through adding another amplifier at the output of the integrator. We also show that the THD can be further improved by means of two cascaded amplifiers with a single pole. We verify our analysis by means of PSPICE simulations. Simulation results show that the THD of the gain boosting and the two cascaded amplifiers with a single pole CDAs can be improved by as much as 1.4 times and 2 times, respectively.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.