Abstract

Paralleling the introduction of Intensity Modulated Radiation Therapy(IMRT) in the early to mid 1990s, Image Guided Radiation Therapy(IGRT) is an important but problematic new tool for the RadiationOncology community. The challenges are similar to IMRT in that IGRT is a general classification that covers many different approaches with numerous variations. Where IMRT ranges from tomotherapy to conventional MLC‐based dose delivery with many different treatment planning approaches, IGRT covers a broad spectrum of techniques ranging from stereoscopic x‐ray imaging with rigid‐body fusion to cone‐beam volume imaging with deformable registration. Thus, like IMRT, guaranteeing the safe and effective use of this new modality in a clinical trial setting will require procedures that are as comprehensive as the ones currently in place for IMRT. As quality assurance techniques are developed for routine clinical use of advanced technologies like IGRT, they must also be appropriately standardized for use in clinical trials. Image Guidance is defined here as the steps of obtaining daily in‐room images of the patient in the treatment position, matching or fusing these images to the ones obtained during the treatment planning process, and the procedure of manually or automatically changing the patient's position based on the fusioninformation. Notice that this description does not consider the patient as a deformable object. Using this simple definition, two Radiation Therapy Oncology Group (RTOG) protocols employ IGRT for targeting the lesion. Both of these protocols require institutions to verify their IGRT methodology through a credentialing process. This process is aimed at guaranteeing that each institution understands the protocol requirements relative to the use of their fusion software or manual shift capabilities. This presentation will discuss the process used by the RTOG to credential institutions for the use of IGRT in their protocols, and it will present the problems and considerations that will have to be addressed as the definition of IGRT expands to include moving targets and deformable fusion. Educational Objectives: 1. To develop a working definition of IGRT that includes imagefusion and patient repositioning. 2. To understand how IGRT is currently being used in RTOG protocols. 3. To understand how the RTOG credentials institutions to use daily imaging and imagefusion in clinical trails. 4. To describe future challenges and to outline how they might be addressed.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call