Abstract

We compare the results of an X-ray based pole figure texture analysis with the local texture analysis by means of electron-backscatter diffraction (EBSD) analysis. As samples, we employ two different melt-textured YBCO samples; one fully processed and one without oxygen treatment. To enable the direct comparison of the two techniques, we employ the [1 0 3] pole figures. We find a clear coincidence between the results obtained by the two measurement techniques on our samples, however, the EBSD results are much more detailed, yielding the local grain orientation distribution and quantitative results of the grain or subgrain misorientation angles. Therefore, the EBSD measurements give information not accessible to the X-ray pole figure analysis. The surface preparation procedure is essential to enable the automated EBSD mapping as high image quality Kikuchi patterns are required. The polishing procedures are discussed in detail.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call