Abstract

A 57 years old male presented to the ED with blunt trauma due to a high fall. On presentation the patient was unstable (Systolic BP- 70, HR -120). The procedure was performed in two sessions. An emergency deployment of a Zenith Alpha (COOK Medical) thoracic endo-graft in the descending thoracic aorta with intentional covering of the left subclavian artery. The patient was stabilized in ICU. Due to left upper limb ischemia a parallel "chimney" Be-Graft (BENTLEY) covered balloon expandable stent was deployed in the left subclavian artery (retrograde approach) after 24 hours from the index procedure. Patient was mobilized with complete recovery after 48 hours. Completion CTA revealed complete resolution of the thoracic rupture with patent left subclavian "chimney" stent.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.