Abstract

Repair of tetralogy of Fallot (ToF) can be challenging in the presence of an abnormal coronary artery (CA) in 5-12% of cases. The aim of this study was to report our experience with ToF repair without the systematic use of a right ventricle-to-pulmonary artery (RV-PA) conduit. We conducted a monocentric retrospective study from 2000 to 2016, including 943 patients with ToF who underwent biventricular repair, of whom 8% (n = 76) presented with an abnormal CA. Mean follow-up time was 50 months (1 month-18 years). The most frequent CA anomaly was the left descending artery arising from the right CA (n = 47, 61.8%). The median age at repair was 7.7 months (1.8 months-16 years). Thirteen patients (17%) required prior palliation, mostly systemic pulmonary shunts for anoxic spells in the neonatal period. Surgical repair allowed us to preserve the annulus in 40 patients (53%) by combining PA trunk plasty, commissurotomy and infundibulotomy under the abnormal CA. If the annulus had to be opened (n = 35, 46%), a transannular patch was inserted after a vertical incision of the PA trunk and extended obliquely on the RV over the anomalous crossing CA (with an infundibulotomy under the abnormal CA). Three patients (4%) required the insertion of an RV-PA conduit (1 valved tube and 2 RV-PA GORE-TEX tubes with annulus conservation). The early mortality rate was 4% (n = 3); none of the deaths was coronary related. Four patients (5%) required reoperation (2 early and 2 late reoperations) for residual pulmonary stenosis, 3 of whom had annulus preservation during the initial repair. The mean RV/left ventricle (LV) pressure ratio and an RV/LV pressure ratio >2/3 were identified as risk factors for right ventricular outflow tract (RVOT) reinterventions (P = 0.0026, P = 0.0085, respectively), RVOT reoperations (P = 0.0002 for both) and reoperation for RVOT residual stenosis (P = 0.0002, P = 0.0014, respectively). Two patients underwent pulmonary valve replacement. Freedom from late reoperation was 100% at 1 year, 97% at 5 years and 84% at 10 and 15 years. Repair of ToF and abnormal CA can be performed without an RV-PA conduit, with an acceptable low reintervention rate. The high early mortality rate in this series remains a concern. If any doubt remains about the surgical relief of the RVOT obstruction, the RV/LV pressure ratio should always be measured in the operating room.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call