Abstract
Length-tension curves were constructed by stimulating tetanically single motor units belonging to the peroneus longus muscle. The lengths at which the motor units showed the maximal tension appeared to be shorter than the length at which the whole muscle developed the maximal twitch tension. Moreover, the optimal lengths appeared to be different for the different motor unit types, corresponding to very short muscle lengths for Slow units and to slightly higher lengths for the Fast Fatiguable and the Fatigue Resistant units.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.