Abstract
According to international standards several safety characteristics of dusts are determined in the 20-L-sphere (also known as SIWEK Chamber). Dust cloud ignition is carried out using pyrotechnical igniters. Due to various disadvantages of such igniters the need for alternative ignition sources arises again and again. An alternative ignition source could be the so called “exploding wire” or “fuse wire. The paper presents test results of a comparative study between both ignition sources for the determination of the safety characteristics Maximum Explosion Pressure and Maximum Explosion Pressure Rise of five selected dusts in the 20-L-sphere. In addition to that the ignition mechanisms of both ignition sources were analysed by high speed camera recordings and the ignition energy was determined with electric and calorimetric recordings.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.