Abstract

Due to rearrangement of the diagnostic positions resulting from the dynamic ergodic divertor installation on TEXTOR, a new antenna pair has been recently installed. This antenna has been designed to test the load resilient “conjugate-T” (CT) mode of operation. The paper describes the calibration of the system and shows from impedance matrix measurements that the load resilience can be maintained in presence of the mutual coupling between the pair. The practical tuning procedure to obtain the load resilience of the system is also described.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.