Abstract

Doppler ultrasound may be used to assess leg blood flow ( ), but the reliability of this method remains unexplored in patients with chronic obstructive pulmonary disease (COPD), where between-subject variability may be larger than healthy due to peripheral vascular changes. This study aimed to investigate the reliability of Doppler ultrasound in quantifying during single-leg knee-extensor exercise (KEE) in COPD patients compared with those obtained from healthy matched controls. In this case-control study, 16 participants with COPD were matched based on sex and age with 16 healthy controls. All participants underwent measurement of using Doppler ultrasound in a KEE set-up at various intensities on two separate visits. Confounding factors on were controlled for, and the ultrasound scans were consistently performed by the same sonographer. During exercise, smallest real difference (SRD) ranged from 367 mL to 583mL in COPD and 438 mL to 667mL in the control group. The coefficient of variation (CV) ranged from 7.9% to 14.3% in COPD and 9.4% to 10.4% in the control group. The intraclass correlation coefficient ranged from 0.75 to 0.92 in COPD and 0.67 to 0.84 in the control group. CV was lower in the control group during exercise at 0W, but apart from that, reliability was not different between groups during exercise. Doppler ultrasound showed nearly equal reliability when evaluating in COPD patients and healthy individuals with a CV below 15% during exercise for both groups. HIGHLIGHTS: What is the central question of this study? What is the between-day reliability of Doppler ultrasound when quantifying leg blood flow during single-leg knee-extensor exercise in COPD patients compared to healthy matched controls? What is the main finding and its importance? This study demonstrates a coefficient of variation ranging from 7.9 to 14.3% during single-leg knee-extensor exercise for between-day reliability when applying Doppler ultrasound to assess leg blood flow in patients with COPD. Furthermore, it offers insights into the peripheral circulatory constraints in COPD, as evidenced by diminished leg blood flow. This study is the first of its kind to evaluate the reliability of Doppler ultrasound in the assessment of the peripheral circulation during exercise in COPD.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.