Abstract

BackgroundPrevious studies have assessed reliability of insole technology for evaluating foot pressure distribution during linear walking. Since in natural motion straight walking is intermingled with turns, we determined the test-retest reliability of insole assessment for curved as well as linear trajectories, and estimated the minimum number of steps required to obtain excellent reliability for each output variable.MethodsSixteen young healthy participants were recruited. Each performed, two days apart, two sessions of three walking conditions: linear (LIN) and curved, clockwise (CW) and counter-clockwise (CCW). The Pedar-X system was used to collect pressure distribution. Foot print was analyzed both as a whole and as subdivided into eight regions: medial and lateral heel, medial and lateral arch, I metatarsal head, II-V metatarsal heads, hallux, lateral toes. Reliability was assessed by using intraclass correlation coefficient (ICC) for clinically relevant variables from analysis of 50 steps per trajectory: Peak Force (PF); Peak Pressure (PP); Contact Area (CA); Stance Duration (S).ResultsWhen considering whole-foot, all variables showed an ICC >0.80, therefore highly reliable. This was true for both LIN and curved trajectories. There was no difference in ICC of the four variables between left and right foot. When collapsing foot and trajectories, S had a lower ICC than PP and CA, and PP lower than CA. Mean percent error between the values of first and second session was <5%. When separately considering the eight foot regions, ICCs of PF, PP and CA for all regions and trajectories were generally >0.90, indicating excellent reliability. In curved trajectories, S showed smaller ICCs. Since the least ICC value for S was 0.60 in LIN trajectory, we estimated that to achieve an ICC ≥0.90 more than 200 steps should be collected.ConclusionsHigh reliability of insole dynamic variables (PF, PP, CA) is obtained with 50 steps using the Pedar-X system. On the contrary, high reliability of temporal variable (S) requires a larger step number. The negligible differences in ICC between LIN and curved trajectory allow use of this device for gait assessment along mixed trajectories in both clinical and research setting.

Highlights

  • Previous studies have assessed reliability of insole technology for evaluating foot pressure distribution during linear walking

  • We considered the output variable Stance Duration, while most other studies have limited their analysis to Peak Force, Peak Pressure and Contact Area [5]

  • The results indicate that a high level of reliability for insole loading variables can be obtained using Pedar-X System

Read more

Summary

Introduction

Previous studies have assessed reliability of insole technology for evaluating foot pressure distribution during linear walking. Since in natural motion straight walking is intermingled with turns, we determined the test-retest reliability of insole assessment for curved as well as linear trajectories, and estimated the minimum number of steps required to obtain excellent reliability for each output variable. Recent studies requiring subjects to travel both linear and circular trajectories have detected abnormalities in patients with neurological disorders. Both Parkinson’s disease [17] and stroke patients [18] showed more severe walking difficulties during circular than linear trajectories

Objectives
Methods
Results
Discussion
Conclusion