Abstract

A 6LiH attenuator of a neutron flux incident on a detector is used to reduce the γ-ray background induced by neutrons in the detector material. This attenuator has been tested during experiments with deuterium (DD) plasmas on the JET tokamak. A specimen of the neutron attenuator with dimensions of ⊘30 × 300 mm has been developed by the Russian Academy of Sciences’ Ioffe Physico-Technical Institute and inserted into a vertical collimator used for γ spectrometry of plasmas. To compare γ-ray spectra recorded with and without the 6LiH attenuator being mounted, identical discharges with heating of the DD plasma by a neutral particle beam have been selected. For γ rays with energies of 3 MeV can be attributed to the transparency of the 6LiH attenuator for γ rays. This portion of the spectrum is due to γ radiation of the plasma and γ rays induced by neutrons in the constructional materials of the tokamak. To estimate the efficiency of the 6LiH attenuators as a mandatory component of the ITER γ-ray diagnostic system, it is necessary that measurements be taken in deuterium-tritium (DT) discharges.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.