Abstract

Presents an approach for fault detection in programmable wiring networks (PWNs). A comprehensive fault model which includes faults in the nets (open, stuck-at and shorts) as well as in the switches (stuck-off, stuck-on and programming faults) is assumed at both the physical and behavioral levels. In a PWN, the most important issue is to find the minimal number of configurations (or programming phases) as the dominant figure of merit of testing. Through the construction of different graphs, it is shown that this process corresponds to finding the node-disjoint path-sets such that each switch is turned on/off at least once and adjacencies in the nets for possible bridge faults (shorts) are verified. To account for 100% fault coverage of bridge faults, a post-processing algorithm may be required.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.