The interference pattern of the optical path difference between an aspherical optical surface and the corresponding best fit spherical surface is the Aspherics Characteristic Interferogram (ACI), which can be used as a template to test aspheric optical surfaces without test plates or null compensation systems. This direct interferometry can be used in the optical shop testing and in the digital phase-shifting spherical Fizeau interferometer to achieve high precise aspheric surface testing automatically. We succeeded in testing several aspheric surfaces by this method. ACI is also the base of phasing segmented mirrors, and six small- segmented mirrors were successfully combinated to a large mirror. If used in the infrared red interferometer, strongly aspheric surfaces with asphericity more than 40micrometers can also be tested. Experiments show that the ACI is a fast, effective aspherical surface measurement technique.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.