Several un-irradiated CFC monoblock mock-ups have been loaded in thermal fatigue tests up to 1000 cycles at power densities <25 MW/m 2. No indication of failure was observed for these loading conditions. Two of the mock-ups were inspected by ultra-sonic methods before thermal cycling. It could be proved that the voids found in the post-mortem metallography existed before and had no effect on the integrity of the mock-up. For the first time, neutron-irradiated CFC monoblock mock-ups have been tested in the electron beam facility JUDITH. These mock-ups had been irradiated before in the High Flux Reactor at Petten up to 0.3 dpa at 320°C and 770°C. All samples showed a significant increase of surface temperature, due to the irradiation induced decrease in thermal conductivity of the CFC materials.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.