Abstract
The provisions of the forthcoming Canadian Highway Bridge Design Code are noted for the design of the external transverse confining system for steel-free deck slabs of girder bridges; according to these provisions, the transverse straps comprising the confining system are required to have a certain minimum axial stiffness, and their connection strength with the deck slab is also specified. The axial stiffness of the straps and their connection strength were studied with the help of pull-out tests on mirror-image models of isolated segments of the deck slab and four different types of strap systems. Three of the tested systems were found to be adequate, and the fourth was considered inadequate because of insufficient connection strength.Key words: arching in slabs, cruciform strap, deck slab, girder bridge, partially studded strap, punching shear, steel-free deck slab, transverse confinement.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.