Abstract

Due to their high bending stiffness, high torsional stiffness, and high local stability, rectangular section members of Al alloy space structures are frequently utilized as load-bearing elements. However, the joint construction is more complex because of the closed cross-section. To join rectangular section members without drilling holes in them, a variety of blind bolts that can be placed and fastened on one side have been devised. The blind bolts researched in this paper is known as BOM bolt. The shear resistance of BOM-bolted Al alloy connections is investigated using shear testing and finite element calculations of individual bolts and bolt groups. According to the test and numerical simulation results, the formulas for the compressive strength of the aluminum plate and the shear capacity reduction factor of BOM-bolted long connections are derived.