Abstract

Abstract The aim of this paper is to investigate the crushing and tensile performance of built-up glass fiber–reinforced polymer (GFRP) pultruded angle sections under compression and tension loads. For the compression test, two GFRP angle sections of size 50 × 50 × 6 mm were selected and maintained the e/d ratio of 5. GFRP angle sections were connected by two-bolt, three-bolt, four-bolt, adhesive, hybrid two-bolt, hybrid three-bolt, and hybrid four-bolt connections. For the tension test, single-lap joint and single-bolt connections were considered. The tension test is performed by angle-to-angle connection with an e/d ratio of 5. Also, the joints were connected by single-bolt connection, hybrid single-bolt with local glue, and hybrid single-bolt with epoxy connection. Based on the studies, the best joint and connection were considered, and a transmission line tower with various connections is modeled and proposed using ANSYS.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.