Abstract

This paper presents an experimental and computational assessment of the performance of steel and reinforced concrete beam-column assemblies under monotonic vertical displacement of a center column, simulating a column removal scenario. The assemblies represent portions of structural framing systems designed as intermediate moment frames (IMFs) and special moment frames (SMFs) for Seismic Design Categories C and D, respectively. The steel IMF and SMF assemblies were designed in accordance with ANSI/AISC 341-02 by using prequalified moment connections specified in FEMA 350. The concrete IMF and SMF assemblies were designed and detailed in accordance with ACI 318-02 requirements. Each full-scale assembly comprises two beam spans and three columns, and downward displacements of the center column are imposed until failure. The study provides insight into the behavior and failure modes of the assemblies, including the development of catenary action. Both detailed and reduced finite-element models are developed,...

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.