Abstract

The double Maddox rod test is often used to measure cyclodeviations and to monitor change over time. The purpose of this study was to estimate test-retest reliability and the amount of cyclodeviation that would be considered real change using 95% limits of agreement. We retrospectively studied 86 clinically stable patients with double Maddox rod measurements 5-175days apart (median, 69days). The range of cyclodeviation at the first measurement was 6° incyclodeviation to 15° excyclodeviation. We calculated the half width of the 95% limits of agreement to be 4.7°, which means that a change of ≥5° in cyclodeviation would be considered a real change. The threshold of 5° should be used when assessing change between two measurements made with double Maddox rods.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.