Abstract

For the new test facility EDIPO (European DIPOle), to be hosted by CRPP, two 18 kA HTS current leads were manufactured and successfully tested. The HTS module, made of AgMgAu/Bi-2223 tapes, is cooled only by heat conduction to the cold end, while the copper part is cooled by forced flow helium gas. The current leads were tested at low voltage up to the maximum current of 18 kA. The helium mass flow rates required for stable operation at various currents were determined. In addition to the steady state operation, the transient behavior in the case of a loss of flow was studied experimentally. The test results provide an estimate of the operational limits of the EDIPO HTS current leads.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.