Abstract

The CaPiRe program has been started to develop a new detector design, in order to produce large areas of glass Resistive Plate Chambers (RPC) detectors, overcoming the previous limitations. As a first step we produced our glass RPC detectors (1m2) at General Tecnica exploiting their standard procedures, materials and production techniques simply using 2 mm glass electrodes instead of the bakelite ones. A set of RPC was produced by using pre-coated (silk screen printed) electrodes, while others were produced with the standard graphite coating. All the detectors, together with four old Glass RPC acting as reference, were tested at the DAΦNE Test Beam Facility with 500MeV electrons in order to study the efficiency in different positions inside the detectors (i.e. near spacers and edges) and to study the detector behavior as a function of the local particle rate.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call