Abstract

Abstract Concrete is more widely used than any other manmade material. The objective of this paper is to investigate the behavior of reinforced cement when migration corrosion and guar gum inhibitors are used. The concrete samples were exposed in aggressive media H2SO4 1 M and in the presence of 1∙10-3 M Cl-. Electrochemical measurements such as half-cell potential, polarization resistance and Tafel extrapolation methods were performed in order to obtain information on the corrosion behavior of the reinforcing steel in cement mortar. Results demonstrate high resistance polarization and low corrosion rate for concrete sample with inhibitor. The corrosion rate decreases approximately 95% in presence of locust bean gum and 80% in presence of migration inhibitor.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.