Abstract

The angular coverage extension of the KLOE-2 electromagnetic calorimeter, from a polar angle of 20 ∘ down to 8 ∘ , will increase the multiphoton detection capability of the experiment enhancing the search reach for rare kaon, η and η ′ prompt decay channels. The basic layout of the calorimeter extension consists of two small barrels of LYSO crystals readout with APD photosensors aiming to achieve a timing resolution between 300 and 500 ps for 20 MeV photons. The first test of a ( 5.5 × 6 × 13 ) cm 3 prototype for such a detector was carried out in April 2009 at the Beam Test Facility of Laboratori Nazionali di Frascati of INFN with an electron beam from 100 to 500 MeV. In the selected energy range, we measured a light yield of 500 – 800 p . e ./ Mev , an energy resolution which can be parametrized as 0.05 ⊕ 0.01 / ( E / GeV ) ⊕ 0.015 / E / GeV , a position resolution of 2.8 mm and a timing resolution of 200 – 300 ps .

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.