Abstract
In order to analyze the off gases from high temperature chemical waste incineration for PCDD and PCDF a simple sampling train was constructed. The efficiency was checked in the laboratory by connecting it to an experimental set up for the generation of a dioxin loaden gas stream. The experiments demonstrate that the proposed sampling train is adequate for tetra through octachlorinated dioxins and dibenzofurans.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.