Abstract

To investigate the effect of stiffener on the stiffness and strength of T-stubs, 3 T-stub connections without stiffeners and 6 stiffened T-stub connections with varied shape and thickness of stiffeners were tested monotonically. The load carrying capacity, relative deformations of endplates and strains on the stiffeners and endplates were measured. The load-deformation curves of the connections and load-strain curves were presented. The test results showed that the commonly used stiffeners in current Chinese practice often yield or/and buckle prematurely. And the stiffener designed by the method can meet the requirement in CECS102-2002, which demands that the stiffener should be able to force the extended portion of endplates from clamped-free boundary to plates fixed on two adjacent boundaries.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.