Abstract

This work reports the influence of ultrasound alone and combined with ozone for the treatment of real abattoir wastewater. Three different frequencies were studied (44, 300 and 1000kHz) at an applied power of 40W. The injected ozone dose was fixed at 71mg/L and the treatment time varied from 1 to 60min. Using ultrasound alone, 300kHz was the only frequency showing a reduction in chemical oxygen demand (COD, 18% reduction) and biological oxygen demand (BOD, 50% reduction), while no diminution in microbial content was measured for any of the frequencies studied. Combining ultrasound with ozone, on the contrary, led to a significant decrease in COD (44%) and BOD (78%) removal for the three frequencies under study. A complete inactivation of total coliforms (TC) was obtained, as well as a final value of 99CFU/mL in total viable counts (TVC, 5 log reduction). That is, the ozonation-sonication combined system was the only treatment method (compared to sonication and ozonation alone) reaching direct discharge limits, as well as meeting drinking water standards for microbial disinfection (TC and TVC).