The Microwave Limb Sounder on the Aura satellite has a radiometer at 2.5 THz to perform global mapping of OH in the atmosphere. The OH radiometer utilizes two Schottky-diode mixers pumped by an optically pumped THz gas laser local oscillator. The laser was first turned on in space on July 22, 2004, and has performed without issue for more than 30 months. The specifications, design, and modeling of this 2.5 THz laser local oscillator are presented here, along with some of the important design validation and test results.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.