Abstract
Terahertz (THz) direct detectors based on superconducting niobium nitride (NbN) hot electron bolometers (HEBs) with microwave (MW) injection have been studied. Compared to the thermal biasing method, the injected MW is used here to bias the HEB to the optimum point. MW can be expected to be used as the easy read out for the detecting array. The used NbN HEB has an excellent performance as heterodyne detector with the noise temperature of 403 K working at 4.2 K and 0.65 THz. As the result, the noise equivalent power (NEP) of 1.4 pW/Hz1/2 and the response time of 64 ps have been obtained for the direct detectors with MW injection.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.