Abstract

The mechanism of terahertz (THz) pulse coherent detection via two-color laser pulses of various frequency ratios in gas plasma is theoretically investigated. Our investigations demonstrate that except for the commonly used frequency ratio of 2, other uncommon frequency ratios can also be utilized to detect THz pulse, such as 2n, n+1/2 (, n is a positive integer). The well-developed transient photocurrent model is extended to our terahertz detection process. Based on this model, our simulation results can be explained by analyzing the process of asymmetric electron ionization and electron acceleration.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.