Abstract

1. Apparatus for applying a step change of length to an isolated muscle fibre is described. The step was complete in about 0.2 ms.2. Effects of tendon compliance were eliminated by using a spot-follower device and by gripping the tendons with metal clips close to the fibre ends.3. The natural frequency of the force transducer was above 10 kHz.4. Steps of various amplitudes and in either direction were applied to isolated muscle fibres about 6 mm long from the anterior tibial muscle of Rana temporaria during tetanic stimulation. Initial sarcomere length was 2.0-2.2 mum, and temperature was 0-3 degrees C.5. The tension response to a step could be divided into four phases. The initial response was an apparently elastic change during the step itself (phase 1). After the step was completed there was a rapid partial recovery towards the original tension (phase 2, lasting 2-5 ms), followed by a slowing or reversal of recovery (phase 3, 10-50 ms), and finally a much slower return to the original tension (phase 4). Most of this paper is concerned with phases 1 and 2.6. The initial tension change (phase 1) occurred synchronously with the applied length change, indicating that the fibres possess a compliance which is almost linear and almost undamped. Its stiffness is such that an instantaneous shortening of about 4 nm per half-sarcomere would bring the tension to zero from its isometric value.7. The absence of detectable damping during phase 1 indicates that the viscosity of a stimulated fibre is substantially less than the apparent viscosity of a fibre at rest.8. The instantaneous force-extension curve approached the length axis at a sharp angle and a negative tension appeared at the force transducer when a very large step was applied. These observations suggest that the structures responsible for the stiffness of the fibre remain rigid when they are not under tension.9. During the few milliseconds after the step (phase 2) the tension recovered part of the way toward the level which existed before the step. In shortening steps the time course of this recovery was adequately fitted by the sum of four exponential terms, and was similar in steps of different amplitude but with a time scale shorter the larger the step. In stretches the slow components were relatively larger than in releases.10. The tension level, T(2), approached during phase 2 depended only on the total amplitude of the step and not on the time course of the length change, provided it was complete in 1-2 ms. The extreme tension reached during a step could thus vary widely without detectable change in T(2).11. With stretches and releases of up to about 3 nm per half-sarcomere this early recovery was almost complete, so that the curve of T(2) against step amplitude was nearly horizontal. With larger releases the line curved downwards, reaching zero in a release of about 14 nm per half-sarcomere.12. When the temperature was raised both the developed tension and the stiffness increased, but the relative increase was greater for tension than for stiffness. The amount of instantaneous shortening needed to bring tension to zero was therefore also increased.13. A set of empirical equations is given which describe adequately the first few milliseconds of the tension change in response to any imposed time course of shortening.14. The rapid elasticity and early tension recovery resemble the response of a combination of two elastic components and one viscous component. Reasons are given for preferring an interpretation in terms of an undamped compliance in series with a damped compliance (Voigt element) rather than an undamped elasticity in parallel with a series combination of viscous and elastic components (Maxwell element).15. The rapid compliance does not correspond to the ;series elastic component' of two-component theories of muscle contraction.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call