Abstract

The present paper highlights the potential dangers of misplaced nasopharyngeal oxygen cannulae causing secondary pneumo-orbitus and pneumocephalus in two paediatric patients. While this complication is uncommon, early recognition allows prompt and appropriate intervention, with cessation of nasal oxygen, cannula removal, early investigation with computed tomography (CT) head/orbit scan and orbital or cranial decompression, if required. Early CT imaging identifies medial orbital or paranasal sinus fractures, the presence of sinusitis, associated intracranial air and assessment of the degree of orbital or intracranial tension. Antibiotics are not usually required for this type of clean injury unless pre-existing sinusitis is identified. In both cases, direct orbital decompression was performed with excellent results after identification of marked unilateral tense exophthalmos, delayed pupillary reactions to light and ophthalmopegia.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.