Abstract

AbstractCommercially available differential pressure transducers, tensiometers, and a data acquisition system were combined to evaluate soil water tension changes with time within two landfill cover designs used for the shallow land burial of waste materials. A typical error for the differential pressure transducers in the voltage‐pressure calibration curve was estimated to be 0.14 V at a transducer output of 4 V. Tensiometer data collected simultaneously using the data‐acquisition system and a hand‐held manual pressure‐transducer system agreed well (r2 = 0.994). The utility of the tensiometer data acquisition system to collect field data was demonstrated successfully using reference tensiometers with known hydraulic heads. Diurnal fluctuations in tensiometer data collected in the field are discussed relative to future experiments to be performed with the system. In addition, tensiometers with unknown and variable hydraulic heads were used to determine tensiometer response times of approximately 50 min.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.