Abstract

A candidate low activation vanadium (V) alloy, V–4Cr–4Ti (NIFS-HEAT-2), was exposed to liquid lithium (Li) at 973 and 1073 K for up to 1963 h. Contamination by carbon (C) and nitrogen (N) from the Li on the order of thousands of wppm were observed. Oxygen (O) levels were reduced to the several 10 wppm level by Li exposure at 1073 K, but not at 973 K. The Li exposure caused strength degradation as measured by tensile tests at 973 and 1073 K. On the other hand, good ductility was demonstrated after the Li exposure even with the significant contamination of C and N. From microstructural observations, C and N are likely to be scavenged by Ti–C–N type precipitates. Reduction of O was attributed to disappearance of Ti–C–O type precipitates.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.