Abstract

Tensile properties of AZ91D magnesium alloy coated by Plasma Electrolytic Oxidation method for various coating times were investigated. The coatings on AZ91D magnesium alloy showed porous microstructure, and became thicker with increasing the coating time. After tensile test, the coated AZ91D magnesium alloy had lower tensile strength and elongation than the uncoated one. The tensile strength and elongation decreased with increasing the coating time, while the proof stress was almost no changed. The uncoated AZ91D magnesium alloy revealed ductile fracture surface. As the coating time increased, however, the fracture surface was changed to brittle fracture morphologies.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.