Abstract

To evaluate, from 2013 to 2022, how HbA1c, the incidence of acute complications, and use of diabetes technology changed at the national level in Norway and how glycemic control was associated with use of diabetes technology, carbohydrate counting, or participation in a quality improvement project. This longitudinal observational study was based on 27,214 annual registrations of 6,775 children from the Norwegian Childhood Diabetes Registry from 2013 to 2022. Individuals aged >18 years, those with diabetes other than type 1, and those without HbA1c measurements were excluded. The outcome measure was HbA1c. The predictor variables in the adjusted linear mixed-effects model were 1) the use of diabetes technology, 2) the use of carbohydrate counting for meal bolusing, and 3) whether the patient's diabetes team participated in a quality improvement project. Mean HbA1c decreased from 8.2% (2013) to 7.2% (2021), and the proportion of youth reaching an HbA1c <7.0% increased from 13% (2013) to 43% (2022). Insulin pump use increased from 65% (2013) to 91% (2022). Continuous glucose monitoring (CGM) use increased from 34% (first recorded in 2016) to 97% (2022). Insulin pump, CGM, and carbohydrate counting were associated with lower HbA1c and higher achievement of glycemic targets. Girls had a higher mean HbA1c than boys. Mean HbA1c levels were lower in clinics that participated in a quality improvement project for the following 4 years after the project. Diabetes technology, carbohydrate counting, and systematic quality improvement in pediatric departments led to improved glycemic control.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call