Abstract

Right ventricular failure (RVF) after implantation of left ventricular assist device (LVAD) is a dramatic complication. We compared retrospectively two techniques of temporary right ventricular support after LVAD (HeartMate II, Thoratec Corp, Pleasonton, CA, USA) implantation. From 1 January 2006 to 31 December 2012, 78 patients [mean age 52 ± 1.34 years; 15 women (19%)] received a HeartMate II at our institution. Among these, 18 patients (23%) suffered postimplant RVF treated by peripheral temporary right ventricular support. Aetiology of heart failure was ischaemic in 12 (67%) and dilated cardiomyopathy in 6 (33%) patients. The preimplant RV risk score averaged 5.1 ± 0.59. Ten patients were treated using a femorofemoral venoarterial extracorporeal life support (ECLS) and 8 patients were treated using extracorporeal membrane oxygenation as a right ventricular assist device (RVAD) established between a femoral vein and the pulmonary artery via a Dacron prosthesis (RVAD). Duration of RV support was 7.12 ± 5.4 days and 9.57 ± 3.5 days in venoarterial ECLS and vein and the pulmonary artery RVAD groups, respectively (P = 0.32). Three patients (17%) died while under RV support (venoarterial ECLS, n = 2; and vein and the pulmonary artery RVAD, n = 1, P = 0.58). In the venoarterial ECLS group, 6 (60%) patients suffered major thromboembolic complications including thrombosis of the ECLS arterial line (n = 2), ischaemic stroke (n = 2) and thrombosis of the ascending aorta (n = 2). No major complication was observed in the vein and the pulmonary artery RVAD group (P = 0.01). RV support was successfully weaned in 8 (80%) patients of the venoarterial ECLS group and in 7 (87.5%) of the vein and the pulmonary artery RVAD group (P = 0.58). The duration of postimplant intensive care unit stay was not different (respectively, 27.5 ± 18.7 days and 20.0 ± 12.0 days; P = 0.38) between both groups. Temporary support of the failing RV after LVAD implantation using temporary vein and the pulmonary artery RVAD is a promising therapeutic option. This approach provides adequate LVAD pre- and afterload and is associated with significantly less thromboembolic complications.

Highlights

  • Right ventricular failure (RVF) is one of the most serious complications following implantation of a left ventricular assist device (LVAD) and is associated with significant postoperative morbidity and mortality [1]

  • No major complication was observed in the vein and the pulmonary artery right ventricular assist device (RVAD) group (P = 0.01)

  • Since January 2012, we have adopted a simplified technique for temporary RV support using peripheral venopulmonary artery right ventricular support as described by Strauch et al [4, 10]

Read more

Summary

Introduction

Right ventricular failure (RVF) is one of the most serious complications following implantation of a left ventricular assist device (LVAD) and is associated with significant postoperative morbidity and mortality [1]. 15% of recipients of latest generation continuous flow LVADs will experience RVF [2]. Several techniques have been described to support the failing RV after LVAD implantation [4,5,6,7,8,9]. Since January 2012, we have adopted a simplified technique for temporary RV support using peripheral venopulmonary artery right ventricular support (vein and the pulmonary artery RVAD) as described by Strauch et al [4, 10]. The aim of the present study was to evaluate our initial experience with this new technique and to compare it with our previous approach

Objectives
Methods
Results
Conclusion
Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.