Abstract

Temporary hemiepiphysiodesis (TH) using eight-plates is one of the most frequently performed surgeries for correcting angular deformities of the lower extremities in adolescents. Rarely have studies examined children with X-linked hypophosphataemic rickets (X-LHPR) treated with TH using eight-plates. This study was conducted to investigate the efficacy, the endpoint, and the complications of TH using eight-plates to correct angular deformities of the lower extremities in skeletally immature children. We reviewed a total of 26 children (86 physes, 52 knees) with X-LHPR (mean age of 6.2years, range from 2 to 13years) who underwent TH using eight-plate to correct angular deformities of the lower extremities. Radiographs and clinical records of these patients were evaluated for demographic data and related clinical factors. The average correction of the mechanical lateral distal femoral angle (mLDFA) was 11.7 ± 8.7° (range from 1.0 to 29.7°), and the average correction of the mechanical medial proximal tibial angle (mMPTA) was 8.4 ± 5.0° (range from 0.3 to 16.7°). The mean deformity correction time was 22.7months (range from 7 to 60months), and the mean follow-up after eight-plate removal was 43.9months (range from 24 to 101months). Overall, 76.9% (20/26 patients) of the angular deformities of the knee were completely corrected and 15.4% (4/26) of the patients received osteotomy surgery. The femoral correction velocity (0.9° per month) was significantly higher than the proximal tibial (0.6° per month) (p = 0.02). The correction velocity of the mLDFA and mMPTA with the TH procedure was faster than that in the absence of intervention (0.9° vs. 0.2°, 0.7° vs. 0.4° per month, p < 0.05). The correction velocity of the mLDFA (1.2° vs. 0.5° per month, [Formula: see text]) and mMPTA (0.7° vs. 0.5° per month, p = 0.04) of patients whose age ≤ fiveyears old was faster than that of patients whose age > fiveyears old. A total of 69.2% (18/26) patients experienced one TH procedure using eight-plates only. Two patients had screw loosening (2/26, 7.7%). One patient (1/26, 3.8%) had a rebound phenomenon after the removal of eight-plate and had the TH procedure again. There was no breakage, infection, physis preclosure, or limited range of movement found in the follow-up. TH using eight-plates is a safe and effective procedure with a relatively low incidence of complication and rebound, and it could be used as part of a streamlined treatment for younger X-LHPR patients with resistant or progressive lower limb deformity despite optimal medical treatment. Early intervention can achieve better results.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.