Abstract

We propose a novel and simple scheme for a temperature-insensitive strain measurement by using a birefringent interferometer configured by a polarization-maintaining photonic crystal fiber (PM-PCF). The wavelength-dependent periodic transmission in a birefringent interferometer can be achieved by using a PM-PCF between two linear polarizers. Since the PM-PCF is composed of a single material, such as silica, the peak wavelength shift with temperature variation can be negligible because of the small amount of the birefringence change of the PM-PCF with temperature change. The measured temperature sensitivity is −0.3 pm/°C. However, the peak wavelength can be changed by strain because the peak wavelength shift is directly proportion to strain change. The strain sensitivity is measured to be 1.3 pm/μe in a strain range from 0 to 1600 μe. The measurement resolution of the strain is estimated to be 2.1 μe. The proposed scheme has advantages of simple structure and low loss without a Sagnac loop, temperature insensitivity, ease installation, and short length of a sensing probe compared with a conventional PMF-based Sagnac loop interferometer.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.