Abstract
Temperature offset stability of magnetoimpedance sensor is discussed based on experiments accomplished with soft magnetic amorphous material. An amorphous ribbon of Co 67Fe 4Cr 7Si 8B 14 composition was tested in a magnetic shield with adjustable internal temperature. DC resistance and complex components of impedance at frequencies up to 30 MHz were investigated in the temperature range of −20 to +75 °C. The measured data were used for the evaluation of temperature dependence of transverse permeability that is assumed to be a major contributor to the temperature variations of impedance. We also show that thermal treatments of the amorphous ribbon significantly affect the temperature behaviour of GMI. In case of tested alloy, which has very small negative temperature coefficient of resistivity, the achieved equivalent temperature offset drift is −0.27 A/m/K (−340 nT/K).
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.