The investigation of propane-butane counter jets combustion in burners with permeable walls was carried out. The effect of addition of silicon oxide, zircon and carbon powder on combustion regime and temperature of free counter jets was investigated. Temperature measurements were implemented using registration of jets radiation in visible spectral range by means of spectral pyrometry and spectroscopic approaches. The burner devices with permeable porous pipes were demonstrated to be promising for broadening parameters range of stable combustion and increasing energy density in fuel combustion systems.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.