Abstract

We demonstrate the temperature distribution monitoring of a coiled flow channel in a microwave reactor that was designed for microwave-assisted continuous-flow synthesis. The monitoring is conducted using an optical fiber sensing technique, which can monitor the temperature distribution along the coiled flow channel. The sensing system successfully observed the inhomogeneous nature of the microwave heating, and the effect of water flow on the temperature distribution. We discuss the cause of the inhomogeneous heating by comparing the observed temperature distributions and the electric fields inside the reactor, as calculated by numerical simulations.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.