Abstract
According to the time-resolved spectra of four lightning return strokes, the temperatures of arc core channel and the peripheral optical channel surrounding the arc core are investigated by different methods; the temperature distribution along the radial direction of channel on the peak current stage is discussed. The results show that a temperature gradient is formed along the radial direction of channel during the discharge process. With the increasing of the radius, the temperature decreases gradually. The temperature of arc core channel is about 4000–5000K higher than that of the peripheral optical channel. The time evolution of channel temperature shows that the falling of the temperature is very slow compared with the decreasing of the current after their peak values. After the peak current, the channel temperature is still maintained at around 20,000K up to 200–400μs. The heat effect resulting from such a long-time high temperature is the main source of most direct lightning disasters.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
More From: Journal of Atmospheric and Solar-Terrestrial Physics
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.