Abstract

In order to realize the accurate calculation of the temperature field of concrete hydration heat, the paper takes the concrete hydration heat temperature field of the pile cap of Liexi Bridge as a case for simulation analysis. Firstly, a three-dimensional finite element model of concrete hydration heat temperature field is established; Then, the temperature field of the hydration heat of the concrete cushion cap of the Liexi Bridge is simulated. The experimental results show that the maximum actual measured temperature of the core point of concrete hydration heat temperature is 63.1 °C, and the corresponding calculated temperature is 62.2 °C. The maximum actual measured temperature of the surface point is 54.8 °C, and the corresponding calculated temperature is 53.8 °C. The maximum temperature difference between inside and outside is 18.9 °C, and the corresponding calculated temperature is 13.4 °C. The research results show that the calculation model has high accuracy

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.