Abstract
BackgroundOxidized derivatives of polyunsaturated fatty acids, collectively known as oxylipins, are labile bioactive mediators with diverse roles in human physiology and pathology. Oxylipins are increasingly being measured in plasma collected in clinical studies to investigate biological mechanisms and as pharmacodynamic biomarkers for nutrient-based and drug-based interventions. Whole blood is generally stored either on ice or at room temperature prior to processing. However, the potential impacts of delays in processing, and of temperature prior to processing, on oxylipin concentrations are incompletely understood. ObjectiveTo evaluate the effects of delayed processing of blood samples in a timeframe that is typical of a clinical laboratory setting, using typical storage temperatures, on concentrations of representative unesterified oxylipins measured by liquid chromatography-tandem mass spectrometry. DesignWhole blood (drawn on three separate occasions from a single person) was collected into 5 mL purple-top potassium-EDTA tubes and stored for 0, 10, 20, 30, 60 or 120 min at room temperature or on wet ice, followed by centrifugation at 4 °C for 10 min with plasma collection. Each sample was run in duplicate, therefore there were six tubes and up to six data points at each time point for each oxylipin at each condition (ice/room temperature). Representative oxylipins derived from arachidonic acid, docosahexaenoic acid, and linoleic acid were quantified by liquid chromatography tandem mass spectrometry. Longitudinal models were used to estimate differences between temperature groups 2 h after blood draw. ResultsWe found that most oxylipins measured in human plasma in traditional potassium-EDTA tubes are reasonably stable when stored on ice for up to 2 h prior to processing, with little evidence of auto-oxidation in either condition. By contrast, in whole blood stored at room temperature, substantial time-dependent increases in the 12-lipoxygenase-derived (12-HETE, 14-HDHA) and platelet-derived (thromboxane B2) oxylipins were observed. ConclusionThese findings suggest that certain plasma oxylipins can be measured with reasonable accuracy despite delayed processing for up to 2 h when blood is stored on ice prior to centrifugation. 12-Lipoxygenase- and platelet-derived oxylipins may be particularly sensitive to post-collection artifact with delayed processing at room temperature. Future studies are needed to determine impacts of duration and temperature of centrifugation on oxylipin concentrations.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
More From: Prostaglandins, Leukotrienes and Essential Fatty Acids
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.