Abstract

We experimentally determined the suitable conditions of temperature and air pressure for measuring charge and mass compositions of heavy cosmic rays using CR-39 track detectors during long-duration, high-altitude balloon flights. The experiments were carried out utilizing Fe ion beams from Heavy Ion Medical Accelerator (HIMAC). Changes in the track registration sensitivity with temperature were studied at temperatures between 213 and 293 K. The charge and mass shifts around Fe ions are possibly 0.11 cu (charge unit) and 0.47 amu (atomic mass unit) at the temperature deviation between 227 and 243 K at balloon altitude. Decrease in track registration sensitivity as air pressure decreases has been observed between 13 Pa and 27 kPa. The charge and mass shifts around Fe ions are inferred to be 0.02 cu and 0.09 amu, respectively, when pressure varies between 20 and 27 kPa. During balloon flight, air pressure drops below this; therefore, care must be taken to keep the temperature and air pressure of CR-39 detectors within acceptable limits.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.