Abstract

Temperature and electric field along the stress grading system of a form wound coil under repetitive impulse voltage are studied using 2D axisymmetric and 3D models in COMSOL¯ 5.3a. The validity of the 3D model is shown by comparing the results with the measured temperature profile along the stress grading system. The evaluation of both temperature and electric field shows that using a stress grading system based on a micro-varistor characteristic reduces the maximum temperature; however, with an increase in the electric field, which can be reduced to an acceptable level. An optimization on the initial conductivity of the micro-varistor characteristic confirms that desired electric field and temperature rise are achievable by selecting an optimized conductivity characteristic. 2D and 3D simulations show that a proposed stress grading system, which is a combination of an optimized stress grading tape conductivity and minimum conductive armor tape length, has a good temperature and electrical performances under repetitive impulse voltage.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.